Язык сайта: RUS | ENG

Новинки

Компания Avago Technologies представила новые микросхемы ALM-80110 и ALM-80210

 

подробнее >>

Сверхминиатюрные термокомпенсированные кварцевые генераторы

 

подробнее >>

GaN несогласованный транзистор компании RF Micro Devices

 

подробнее >>

Силовой N-канальный МОП-транзистор NTMFS4927N компании ON Semiconductor

 

подробнее >>

Монолитные интегральные схемы СВЧ переключателей компании Hittite Microwave

 

подробнее >>



Все новинки

Smart Relays


Pro-IO 2

The PanelStation 4.7 is a cost effective replacement of hard-wired discrete devices, from push buttons and pilot lights to message centers. The PanelStation decreases the point-to-point wiring while increasing system reliability. Free form static and dynamic graphics present information-rich graphics to the operator. Re-configurable screens simplify system upgrades without re-wiring.

All 4.7 models feature 320x240 pixels display and NEMA 4x/12 ratings. Each unit includes one serial port, and tool port. The serial port supports both RS232 and RS422 communications. These units are excellent choice for OEM machinery to share operator runtime information and developing diagnostic machine troubleshooting guidelines.

pixel Model Line-up

To identify Model Numbers

 
pixel With Display
More than 20 input / output points | 4 models

ModelInputOutput
Input points
(Analog Input points)
Input NormalInput Analog
(Both Analog and Digital)
Output pointsOutput 8AOutput 5A
DR2-B201BD12 (6)I1 to I6IB to IG8Q1 to Q8-
DR3-B261BD16 (6) I1 to IAIB to IG10Q1 to Q8Q9,QA
DR2-B201FU12I1 to IC-8Q1 to Q8-
DR3-B261FU16I1 to IG-10Q1 to Q8Q9,QA
 
Less than 12 input / output points | 4 models

ModelInputOutput
Input points
(Analog Input points)
Input NormalInput Analog
(Both Analog and Digital)
Output pointsOutput 8AOutput 5A
DR2-B121BD8 (4) I1 to I4IB to IE4Q1 to Q4-
DR3-B101BD6 (4) I1 to I2IB to IE4Q1 to Q4-
DR2-B121FU8I1 to I8-4Q1 to Q4-
DR3-B101FU6I1 to I6-4Q1 to Q4-
 
pixel Without Display
20 input / output points | 2 models

ModelInputOutput
Input points
(Analog Input points)
Input NormalInput Analog
(Both Analog and Digital)
Output pointsOutput 8AOutput 5A
DR2-D201BD12 (2)I1 to IAIB , IC 8Q1 to Q8-
DR2-D201FU12I1 to IC-8Q1 to Q8-
 
10 input / output points | 2 models

ModelInputOutput
Input points
(Analog Input points)
Input NormalInput Analog
(Both Analog and Digital)
Output pointsOutput 8AOutput 5A
DR2-D101BD6I1 to I6-4Q1 to Q4-
DR2-D101FU6I1 to I6-4Q1 to Q4-
 
pixel Extension Unit
Extension Unit | 4 models

ModelInputOutput
Input pointsInput NormalOutput pointsOutput 8AOutput 5A
DR3-XT61BD4IH,IJ,IK,IL2QB,QC-
DR3-XT141BD8IH,IJ,IK,IL,IN,IP,IQ,IR6QB to QEQF,QG
DR3-XT61FU4IH,IJ,IK,IL2QB,QC-
DR3-XT141FU8IH,IJ,IK,IL,IN,IP,IQ,IR6QB to QEQF,QG



Application Software and Options

NameModelDescription
PRO-iO2 EditorDR2-SFT01Logic program development editor.
PRO-iO2 Data Transfer CableDR2-CBL01Connects the PRO-iO2 module to a PC to transfer logic programs.
PRO-iO2 Memory PackDR2-MEM01Used with DR*-B***** models to backup (save) logic programs.
Can copy logic programs to other DR*-B*****-type PRO-iO2 modules.



PRO-iO (Old Model) and PRO-iO2"s point of difference

Hardware1.Old transfer cable cannot be used because connector shape has changed.
2.Old memory pack cannot be used because the connector shape is different.
3.Switch arrangement on the unit is different.
4.Terminal numbers changed because the number of analog input points for DC type increased.
5.View mode (VISU menu) in the display setting of the unit eliminated.
6.Backup time is expanded from 150 hours to 10 years.
7.Back light is added.
Software1.The number of lines for program creation increased from 80 to 120 lines.
2.The number of internal coils increased from 15 to 28.
3.Backlight Control command added.
4.High-speed counter input (Max=1kHz) added.
5.PRO-iO2 editor cannot edit and transfer a program to PRO-iO (old model).
pixel FEATURES
Relay Sequence Function

Basic ON/OFF control of a lamp, pump, etc. after receiving an input (a contact, b contact) such as a button or switch, Complex input conditions can also be made combining AND circuits, OR circuits, etc.


Counter Function

With this function an incoming signal is counted and made a pre-set value.

Example: On a product manufacturing line defective products can be detected and counted by a sensor.


Analog (certain models only)

This function inputs the analog signals of two points, temperature, pressure, etc., and outputs a result of the comparison of the two points and a set value.

Example: If temperatures rises too high in a greenhouse, a window will be opened automatically.


Timer Function

After receiving an incoming signal, unit waits a pre-set amount of time, then sends output.

Example: A washing machine switch is pushed, washing is started, and it stopped after 40 seconds.


Calender Function

This output function allows scheduling of regular events, such as weekly or daily.

Example: Equipment can be prepared for operation, such as having pre-heating every day at 6:00am.


HOW TO ORDER

Visit the online Product Pricing at Xycom.com for order numbers and pricing.
pixel DOCUMENTATION
Pro-IO 2: Smart Logic Relay Modules

Новости

Компания Silicon Laboratories представила серию Si51x
в которую входят кварцевые генераторы и кварцевые генераторы
подробнее >>

Компания KEMET представила керамические чип-конденсаторы
предназначенные для монтажа на единую монолитную структуру.
подробнее >>

С праздником 23 февраля

 

подробнее >>

Генераторы с низкой G-чувствительностью
 для военных и промышленных приложений
подробнее >>

Cнижение цен на модели

драйверов светодиодов AIMTEC

подробнее >>



Все новости