Новинки
Компания Avago Technologies представила новые микросхемы ALM-80110 и ALM-80210
подробнее >>
Сверхминиатюрные термокомпенсированные кварцевые генераторы
подробнее >>
GaN несогласованный транзистор компании RF Micro Devices
подробнее >>
Силовой N-канальный МОП-транзистор NTMFS4927N компании ON Semiconductor
подробнее >>
Монолитные интегральные схемы СВЧ переключателей компании Hittite Microwave
подробнее >>
Все новинки
|
Smart Relays
Pro-IO 2 |
|
The PanelStation 4.7 is a cost effective replacement
of hard-wired discrete devices, from push buttons and pilot lights to
message centers. The PanelStation decreases the point-to-point wiring
while increasing system reliability. Free form static and dynamic
graphics present information-rich graphics to the operator.
Re-configurable screens simplify system upgrades without re-wiring.
All 4.7 models feature 320x240 pixels display and NEMA 4x/12 ratings.
Each unit includes one serial port, and tool port. The serial port
supports both RS232 and RS422 communications. These units are excellent
choice for OEM machinery to share operator runtime information and
developing diagnostic machine troubleshooting guidelines. |
Model Line-up |
To identify Model Numbers
| |
With Display |
More than 20 input / output points | 4 models
|
Model | Input | Output | Input points (Analog Input points) | Input Normal | Input Analog (Both Analog and
Digital) | Output points | Output 8A | Output 5A | DR2-B201BD | 12 (6) | I1 to I6 | IB to IG | 8 | Q1 to Q8 | - | DR3-B261BD | 16 (6) | I1 to IA | IB to IG | 10 | Q1 to Q8 | Q9,QA | DR2-B201FU | 12 | I1 to IC | - | 8 | Q1 to Q8 | - | DR3-B261FU | 16 | I1 to IG | - | 10 | Q1 to Q8 | Q9,QA |
|
Less than 12 input / output points | 4 models
|
Model | Input | Output | Input points (Analog Input points) | Input Normal | Input Analog (Both Analog and
Digital) | Output points | Output 8A | Output 5A | DR2-B121BD | 8 (4) | I1 to I4 | IB to IE | 4 | Q1 to Q4 | - | DR3-B101BD | 6 (4) | I1 to I2 | IB to IE | 4 | Q1 to Q4 | - | DR2-B121FU | 8 | I1 to I8 | - | 4 | Q1 to Q4 | - | DR3-B101FU | 6 | I1 to I6 | - | 4 | Q1 to Q4 | - |
|
Without Display |
20 input / output points | 2 models
|
Model | Input | Output | Input points (Analog Input points) | Input Normal | Input Analog (Both Analog and
Digital) | Output points | Output 8A | Output 5A | DR2-D201BD | 12 (2) | I1 to IA | IB , IC | 8 | Q1 to Q8 | - | DR2-D201FU | 12 | I1 to IC | - | 8 | Q1 to Q8 | - |
|
10 input / output points | 2 models
|
Model | Input | Output | Input points (Analog Input points) | Input Normal | Input Analog (Both Analog and
Digital) | Output points | Output 8A | Output 5A | DR2-D101BD | 6 | I1 to I6 | - | 4 | Q1 to Q4 | - | DR2-D101FU | 6 | I1 to I6 | - | 4 | Q1 to Q4 | - |
|
Extension Unit |
Extension Unit | 4 models
|
Model | Input | Output | Input points | Input Normal | Output points | Output 8A | Output 5A | DR3-XT61BD | 4 | IH,IJ,IK,IL | 2 | QB,QC | - | DR3-XT141BD | 8 | IH,IJ,IK,IL,IN,IP,IQ,IR | 6 | QB to QE | QF,QG | DR3-XT61FU | 4 | IH,IJ,IK,IL | 2 | QB,QC | - | DR3-XT141FU | 8 | IH,IJ,IK,IL,IN,IP,IQ,IR | 6 | QB to QE | QF,QG |
Application Software and Options
Name | Model | Description | PRO-iO2 Editor | DR2-SFT01 | Logic program development editor. | PRO-iO2 Data Transfer Cable | DR2-CBL01 | Connects the PRO-iO2 module to a PC to transfer
logic programs. | PRO-iO2 Memory Pack | DR2-MEM01 | Used with DR*-B***** models to backup (save)
logic programs. Can copy logic programs to other
DR*-B*****-type PRO-iO2 modules. |
PRO-iO (Old Model) and PRO-iO2"s point of difference
Hardware | 1.Old transfer cable
cannot be used because connector shape has changed. | 2.Old memory pack cannot be used
because the connector shape is different. | 3.Switch arrangement on the unit is
different. | 4.Terminal numbers changed because
the number of analog input points for DC type increased. | 5.View mode (VISU menu) in the
display setting of the unit eliminated. | 6.Backup time is expanded from 150
hours to 10 years. | 7.Back light is added. | Software | 1.The number of lines for program
creation increased from 80 to 120 lines. | 2.The number of internal
coils increased from 15 to 28. | 3.Backlight Control command
added. | 4.High-speed counter input
(Max=1kHz) added. | 5.PRO-iO2 editor cannot edit
and transfer a program to PRO-iO (old
model). |
|
FEATURES |
Relay Sequence Function
Basic ON/OFF control of a lamp, pump, etc. after receiving an input (a
contact, b contact) such as a button or switch, Complex input conditions
can also be made combining AND circuits, OR circuits, etc.
Counter Function
With this function an incoming signal is counted and made a pre-set
value.
Example: On a product manufacturing line defective products can be
detected and counted by a sensor.
Analog (certain models only)
This function inputs the analog signals of two points, temperature,
pressure, etc., and outputs a result of the comparison of the two points
and a set value.
Example: If temperatures rises too high in a greenhouse, a window
will be opened automatically.
Timer Function
After receiving an incoming signal, unit waits a pre-set amount of time,
then sends output.
Example: A washing machine switch is pushed, washing is started, and
it stopped after 40 seconds.
Calender Function
This output function allows scheduling of regular events, such as weekly
or daily.
Example: Equipment can be prepared for operation, such as having
pre-heating every day at 6:00am.
HOW TO ORDER
Visit the online Product Pricing at Xycom.com for order numbers and
pricing. |
DOCUMENTATION |
Pro-IO 2: Smart Logic Relay Modules
|
|
Новости
Компания Silicon Laboratories представила серию Si51x
в которую входят кварцевые генераторы и кварцевые генераторы
подробнее >>Компания KEMET представила керамические чип-конденсаторы
предназначенные для монтажа на единую монолитную структуру.
подробнее >> С праздником 23 февраля
подробнее >>Генераторы с низкой G-чувствительностью
для военных и промышленных приложений
подробнее >>Cнижение цен на модели
драйверов светодиодов AIMTEC
подробнее >>
Все новости
|