Новинки
Компания Avago Technologies представила новые микросхемы ALM-80110 и ALM-80210
подробнее >>
Сверхминиатюрные термокомпенсированные кварцевые генераторы
подробнее >>
GaN несогласованный транзистор компании RF Micro Devices
подробнее >>
Силовой N-канальный МОП-транзистор NTMFS4927N компании ON Semiconductor
подробнее >>
Монолитные интегральные схемы СВЧ переключателей компании Hittite Microwave
подробнее >>
Все новинки
|
1300 OpenCLIENT™ Industrial ThinClient Node
|
OpenCLIENT Terminals & Nodes are industrially
hardened platforms used for terminal server network applications.
OpenCLIENT terminals are designed to support ACP"s ThinManager server
software. Several OpenCLIENT models are available based on your screen
size and resolution requirements. |
FEATURES |
Reduced Maintenance Costs
Because all programs are centrally stored in the server, you can simply
upgrade to the latest version of software, make any changes needed to
the screens (one time, on the server) and every client in the factory is
running the latest code with the updated screens.
The OpenCLIENT is a solid, rugged piece of equipment, with no moving
parts of any kind, greatly increasing its MTBF. If the device is
accidentally destroyed however, the program continues to run on the
server and the application data is unaffected. To replace a damaged unit,
the operator plugs in a replacement OpenCLIENT and turns it on. Once the
client boots, it displays the same screen as the previous client.
OpenCLIENTs can be powered down and back up at any time without the risk
of data loss or damage to the disk directory
structure.
Enhanced Security
If an operator powers down a traditional PC while it is running there is
a good chance that it will go through a disk checking procedure at
startup. At that time it can be halted or restarted to gain control. A
malicious operator could insert a boot disk and restart the PC to add
his own programs, or worse enter setup mode during the power-up sequence.
The OpenCLIENT avoids both of these weaknesses. It has no disk drives
and does not go through the traditional PC power-up sequence.
Simplified Fault Tolerance
If a plant using individual Industrial PCs is really concerned with
redundancy or fault tolerance, they must invest money to add special
features to every PC in their plant. With a thin client system the IT
department simply makes the server redundant and all clients linked to
that server become redundant as well.
ThinClient Managememt Software
ThinManager™ software is as easy to read as it is to use. Administrators
can simply glance at the management screen and see which terminals are
online. They can create a new terminal, or replace a damaged terminal.
With ThinManager"s "Default" and "AutoCreate" features, any terminal
that has not been booted from that server before can be automatically
created and logged in using the parameters of the Default terminal.
Clients can therefore be replaced and added directly from the floor
without visiting the server. Clients at different locations frequently
have different functions, requiring different configurations. If an
OpenCLIENT must be reconfigured, the system administrator can restart it
from the management interface. Since the client"s software is running on
the server, this will not affect the operation of any applications that
are being displayed on the client.
OpenCLIENT terminals running the same
application may have similar characteristics. In this case, terminals
can be grouped together to provide a visually useful method of checking
on the status of all of the clients in that group. Terminals added to
the group will inherit all of the
group"s settings. Grouping terminals also makes it easy to apply
configuration changes to every member of the group.
Special Features for Industrial Applications
OpenCLIENT™ workstations also support industry specific protocols
including DeviceNet, Profibus and high-speed serial ports. The
ThinManager software will detect the OpenCLIENT"s model number and build
a basic set of modules to support its features. Settings are saved in a
file on the server, so wherever these OpenCLIENT terminals are installed
they will always receive the correct software during boot up.
Flat Panel Monitor Connectivity
OpenCLIENT Nodes (1300 and 1401 models) support connectivity to Xycom
Flat Panel Monitors creating a complete industrial solution. |
ADDITIONAL
FEATURES |
Enabled by ACP ThinManager (ThinManager sold separately)
No-integrated display
Reprogrammable keypad or analog resistive touchscreen
Built-in PCI 10/100 BaseT Ethernet
PC/104 expansion - one card on 1300 models
NS Geode GX1 300 MHz processors
128 MB DRAM
Parallel, RS-232 and RS-485, PS/2 mouse and keyboard, and VGA ports
NEMA 4/4X/12 front panel (units with integrated displays) |
TECHNICAL
SPECIFICATIONS |
Processor: NS Geode GX1 5x86 300 MHz
System Ram: 128 MB
Integrated Video Connector Supports:
VGA (640 x 480)
SVGA (800 x 600)
XGA (1024 x 768)
SXGA (1280 x 1024)
Ethernet: Built-in 10/100 BaseT
Expansion: PC/104 expansion (one card only) |
SPECIFICATIONS |
Power Supply: 55 Watt power
AC Power: 100-240V AC, autoranging, 50/60 Hz, 0.5 A (maximum), 21 W
nominal*
DC Power: 18-32V DC, 24V nominal, 0.9 A (maximum), 21 W nominal*
*Nominal Power is measured for a base configuration only. Any
additional expansion and/or devices will increase the input power
required. |
STANDARDS &
RATINGS |
UL
UL 508 Listed
cUL
CSA-C22.2, #142 Listed
Temp. Code: T6 |
COMPLIANCE |
CE
EN 55022, Class A
EN 61000-6-2
EN 61000-3-2, Class A
EN 61000-3-3
IEC 60950-1
FCC
47 CFR, Part 15 Class A |
DIMENSIONS |
Refer to product datasheet for product dimensions. |
WARRANTY |
The 1300 node carries a one-year warranty on parts & labor. Extended
warranties available. |
HOW TO ORDER |
1300-CLIENT-AC-ACP: OpenCLIENT 1300 Industrial ThinCLIENT Node with 128
MB SDRAM |
DOCUMENTATION |
OpenClient Industrial Windows® Terminals - ACP Enabled (includes 1300, 1401, 33XX) (hi-res PDF)
OpenClient Industrial Windows® Terminals - ACP Enabled (includes 1300, 1401, 33XX) (low-res PDF)
Industrial PC / FP Monitor Products: New Generations of Industrial PC Technology
1300XXX CE Certification
UL Auxiliary Devices Certification for US (NKCR.E107636)
UL Auxiliary Devices Certification for Canada (NKCR7.E107636)
UL Information Technology Equipment Including Electrical Business Equipment Certification for US (NWGQ.E181675)
UL Information Technology Equipment Including Electrical Business Equipment Certification - Component for US (NWGQ2.E181675) |
|
Новости
Компания Silicon Laboratories представила серию Si51x
в которую входят кварцевые генераторы и кварцевые генераторы
подробнее >>Компания KEMET представила керамические чип-конденсаторы
предназначенные для монтажа на единую монолитную структуру.
подробнее >> С праздником 23 февраля
подробнее >>Генераторы с низкой G-чувствительностью
для военных и промышленных приложений
подробнее >>Cнижение цен на модели
драйверов светодиодов AIMTEC
подробнее >>
Все новости
|