Cables with increased environmental tolerance
| |
ÖLFLEX® CLASSIC 100 H |
Application: |
Environmentally friendly, halogen-free Power Connecting and Control Cable
Especially for electrical equipment and installations in industrial
environments, dry or damp interiors
Suitable for fixed installation under medium mechanical load conditions as
well as for flexing application at free, non-continuously recurring movement
without tensile load or compulsory guidance
Outdoor use with UV-protection only, considering the temperature range
Not for direct burial
Area of use:
Public facilities
Airport, Railway Station
Plant engineering and construction
Air conditioning systems
Machine tools
Data processing systems
Particularly where human and animal life as well as valuable property are
exposed to high risk of fire hazards
|
Advantage: |
Due to the halogen-free materials, the formation of toxic dioxins and
furanes in the case of fire is considerably reduced
High resistance against oils, grease and their emulsions, thereby suitable for
use in areas of stock-removing machine tools
The newly developed, non cross-linked and halogen-free material is completely
recyclable
In combination:
Halogen free acc.to IEC 60754-1 (Amount of halogen acid gas)
Corrosiveness of combustion gases acc. to IEC 60754-2 (Degree of acidity)
Toxicity of combustion gases acc. to NES 713 Part 3
Low smoke density acc. to IEC 61034
No flame propagation acc. to IEC 60332-3-24 or IEC 60332-3-25 (Flame spread on
vertical cable or wire bundle)
Oil resistant acc. to SEV TB 20 B
Asbestos-, CFC-, lead- and silicone-free
Hydrolysis-resistant HD 22.10
Flame retardant acc. to IEC 60332-1-2 (Flame spread on single cable or wire)
| |
ÖLFLEX® CLASSIC 110 H |
Application: |
Environmentally friendly, halogen-free Control Cable
Especially for electrical equipment and installations in industrial
environments, dry or damp interiors
Suitable for fixed installation under medium mechanical load conditions as
well as for flexing application at free, non-continuously recurring movement
without tensile load or compulsory guidance
Outdoor use with UV-protection only, considering the temperature range
Not for direct burial
Area of use:
Public facilities
Airport, Railway Station
Machine tools
Plant engineering and construction
Electrical machines and devices
Air conditioning systems
Office machines
Data processing systems
Particularly where human and animal life as well as valuable property are
exposed to high risk of fire hazards
|
Advantage: |
Due to the halogen-free materials, the formation of toxic dioxins and
furanes in the case of fire is considerably reduced
High resistance against oils, grease and their emulsions, thereby suitable for
use in areas of stock-removing machine tools
The newly developed, non cross-linked and halogen-free material is completely
recyclable
In combination:
Halogen free acc.to IEC 60754-1 (Amount of halogen acid gas)
Corrosiveness of combustion gases acc. to IEC 60754-2 (Degree of acidity)
Low toxicity of smoke gases NES 713 Part 3
Low smoke density acc. to IEC 61034
No flame propagation acc. to IEC 60332-3-24 or IEC 60332-3-25 (Flame spread on
vertical cable or wire bundle) For sizes ≥ 7x1mm²
Oil resistant acc. to SEV TB 20 B
Asbestos-, CFC-, lead- and silicone-free
Hydrolysis-resistant HD 22.10
Flame retardant acc. to IEC 60332-1-2 (Flame spread on single cable or wire)
| |
ÖLFLEX® CLASSIC 110 CH |
Application: |
Environmentally friendly, EMC-compliant, halogen-free Control Cable
Especially for electrical equipment and installations in industrial
environments, dry or damp interiors
Suitable for fixed installation under medium mechanical load conditions as
well as for flexing application at free, non-continuously recurring movement
without tensile load or compulsory guidance
Outdoor use with UV-protection only, considering the temperature range
Not for direct burial
Area of use:
Public facilities
Airport, Railway Station
Plant engineering and construction
Electrical machines and devices
Air conditioning systems
Office machines
Data processing systems
Particularly where human and animal life as well as valuable property are
exposed to high risk of fire hazards
|
Advantage: |
Due to the halogen-free materials, the formation of toxic dioxins and
furanes in the case of fire is considerably reduced
High resistance against oils, grease and their emulsions, thereby suitable for
use in areas of stock-removing machine tools
The newly developed, non cross-linked and halogen-free material is completely
recyclable
In combination:
Halogen free acc.to IEC 60754-1 (Amount of halogen acid gas)
Corrosiveness of combustion gases acc. to IEC 60754-2 (Degree of acidity)
Low toxicity of smoke gases NES 713 Part 3
Low smoke density acc. to IEC 61034
No flame propagation acc. to IEC 60332-3-24 or IEC 60332-3-25 (Flame spread on
vertical cable or wire bundle)
Oil resistant acc. to SEV TB 20 B
Asbestos-, CFC-, lead- and silicone-free
Hydrolysis-resistant HD 22.10
Flame retardant acc. to IEC 60332-1-2 (Flame spread on single cable or wire)
| |
ÖLFLEX® 120 H |
Application: |
Especially for electrical equipment and installations in industrial
environments, dry or damp interiors
Suitable for fixed installation under medium mechanical load conditions as
well as for flexing application at free, non-continuously recurring movement
without tensile load or compulsory guidance
Outdoor use with UV-protection only, considering the temperature range
Not for direct burial
Area of use:
Public facilities
Airport, Railway Station
Plant engineering and construction
Electrical machines and devices
Air conditioning systems
Data processing systems
Particularly where human and animal life as well as valuable property are
exposed to high risk of fire hazards
|
Advantage: |
Due to the halogen-free materials, the formation of toxic dioxins and
furanes in the case of fire is considerably reduced
The newly developed, non cross-linked and halogen-free material is completely
recyclable
In combination:
Halogen free acc.to IEC 60754-1 (Amount of halogen acid gas)
Corrosiveness of combustion gases acc. to IEC 60754-2 (Degree of acidity)
Low toxicity of smoke gases NES 713 Part 3
Low smoke density acc. to IEC 61034
Asbestos-, CFC-, lead- and silicone-free
Hydrolysis-resistant
Easier to handle whilst laying and connecting
Cold flexible up to -25°C.
| |
ÖLFLEX® 120 CH |
Application: |
Environmentally friendly, halogen-free Control Cable
Especially for electrical equipment and installations in industrial
environments, dry or damp interiors
Suitable for fixed installation under medium mechanical load conditions as
well as for flexing application at free, non-continuously recurring movement
without tensile load or compulsory guidance
Outdoor use with UV-protection only, considering the temperature range
Not for direct burial
Area of use:
Public facilities
Airport, Railway Station
Plant engineering and construction
Electrical machines and devices
Air conditioning systems
Data processing systems
Particularly where human and animal life as well as valuable property are
exposed to high risk of fire hazards
|
Advantage: |
Due to the halogen-free materials, the formation of toxic dioxins and
furanes in the case of fire is considerably reduced
The newly developed, non cross-linked and halogen-free material is completely
recyclable
In combination:
Halogen free acc.to IEC 60754-1 (Amount of halogen acid gas)
Corrosiveness of combustion gases acc. to IEC 60754-2 (Degree of acidity)
Low toxicity of smoke gases NES 713 Part 3
Low smoke density acc. to IEC 61034
Asbestos-, CFC-, lead- and silicone-free
Hydrolysis-resistant
Easier to handle whilst laying and connecting
Cold flexible up to -25°C.
| |
ÖLFLEX® CLASSIC 130 H |
Application: |
Environmentally friendly, halogen-free Control Cable
Especially in industrial and/or EMC-critical environments
For fixed installation as well as for flexible application at free,
non-continuously recurring movement
Area of use:
Public facilities
Airport, Railway Station
Plant engineering and construction
Air conditioning systems
Particularly where human and animal life as well as valuable property are
exposed to high risk of fire hazards
Amendment: Single conductor or multi-conductor Type AWM (Appliance Wiring
Material) shall be permitted for industrial machinery (US) when part of a listed
assembly suitable for the intended use only. NFPA 79 Edition 2007 §12.2.7.3 (Electrical
Standard for Industrial Machinery)
|
Advantage: |
Halogen free acc.to IEC 60754-1 (Amount of halogen acid gas)
Corrosiveness of combustion gases acc. to IEC 60754-2 (Degree of acidity)
Toxicity of combustion gases acc. to NES 713 Part 3
Low smoke density acc. to IEC 61034
No flame propagation acc. to IEC 60332-3-24 or IEC 60332-3-25
Flame retardant acc. to IEC 60332-1-2 (Flame spread on single cable or wire)
Asbestos-, CFC-, lead- and silicone-free
UL AWM types acc. to Style 21089
Flame retardant acc. to UL 1581 §1080 (VW-1)
| |
ÖLFLEX® CONTROL TM |
Application: |
Environmentally friendly, halogen-free Control Cable
Especially in industrial and/or EMC-critical environments
For fixed installation as well as for flexible application at free,
non-continuously recurring movement
Area of use:
Public facilities
Airport, Railway Station
Plant engineering and construction
Air conditioning systems
Particularly where human and animal life as well as valuable property are
exposed to high risk of fire hazards
Amendment: Single conductor or multi-conductor Type AWM (Appliance Wiring
Material) shall be permitted for industrial machinery (US) when part of a listed
assembly suitable for the intended use only. NFPA 79 Edition 2007 §12.2.7.3 (Electrical
Standard for Industrial Machinery)
|
Advantage: |
Halogen free acc.to IEC 60754-1 (Amount of halogen acid gas)
Corrosiveness of combustion gases acc. to IEC 60754-2 (Degree of acidity)
Toxicity of combustion gases acc. to NES 713 Part 3
Low smoke density acc. to IEC 61034
No flame propagation acc. to IEC 60332-3-24 or IEC 60332-3-25
Flame retardant acc. to IEC 60332-1-2 (Flame spread on single cable or wire)
Asbestos-, CFC-, lead- and silicone-free
UL AWM types acc. to Style 21089
Flame retardant acc. to UL 1581 §1080 (VW-1)
| |
| |
|
Новости
Компания Silicon Laboratories представила серию Si51x
в которую входят кварцевые генераторы и кварцевые генераторы
подробнее >>Компания KEMET представила керамические чип-конденсаторы
предназначенные для монтажа на единую монолитную структуру.
подробнее >> С праздником 23 февраля
подробнее >>Генераторы с низкой G-чувствительностью
для военных и промышленных приложений
подробнее >>Cнижение цен на модели
драйверов светодиодов AIMTEC
подробнее >>
Все новости
|